Request Shipping Quote
We'll submit your offer right away and will let you know as soon as the seller responds
Want to speak to the seller? Call us at 1-847-854-8577
Brand: Daikin Industries Ltd. Model: AKZ569MFG Number: 1011-218-00620Product Year: 2021Description:AKZ569Oil Cooling Unit 9 Series3-Phase200/220 VAC50/60 Hz5-5.6 KW Cooling Capacity Compact Design (Compact design of top class in the industry)High-Accuracy type with inverter compressor and electronic expansion valveCirculation type Oil Cooling Unit (Built-in circulation pump)Closed type coolerNew refrigerant R410A (Modulus of rupture of ozone layer: 0)Temperature control in low-load range attained by wide cooling capacity control (Conventional: 10~100%→9 series: 5~100%)Wide operating temperature range (Room temperature: 5~45℃, Inlet oil temperature: 5~50℃)1. The first class energy-savingDaikin original IPM motor and new refrigerant R410A provide the first class energy-savi2. Low noise59.5dB (A)→ 58dB (A) with AKZ439 class *corresponding value in anechoic chamberGenerally, people can talk at the distance of 1m at the noise level of 60dB.3. High-Accuracy temperature controlHigh-Accuracy model with the inverter-controlled compressor4. Easy monitoring of operating statusThe room temperature, inlet and outlet oil temperatures and other internal data can be monitored at a personal computer using Hybrid-Win*. This data can be displayed collectively, making it easy to grasp the operating status.5. RoHS CompliantComplies with the RoHS Directive, e.g. by adopting printed circuit boards with lead-free solder.6. Reinforce durability for mist or dust in the severe condition of factoryThe ingress protection of the control box has been upgraded (equivalent to IP54).Electronic components resistant to sulfidization have been adopted.7. Higher durability for long-distance transportationThe specifications for withstanding vibration during transport have been upgraded to reflect actual transportation conditions.8. Functions featured· Refrigerant gas leakage detection alarm function· An alarm signal is output when the refrigerant gas would be leaked (as cooling circuit failure).· Oil temperature warning function· A warning signal can be output when the oil temperature or air temperature strays outside arbitrarily setting range.· Preventive maintenance function· A warning signal is output to notify that maintenance is required when the air filter or condenser becomes clogged.· If the thermistor fails (out of control), emergency operation is possible by selecting another operation mode. This function minimizes the factors of line stoppages.· Auto tuning function· This function substantially cuts the time taken for adjustment during trial operation by automatically setting the gain when oil temperature control is not stable in the factory setting status or when optimization is required.· 999-hour timer function (ON timer)· The operation start time can be set from 0 to 999 hours in one-hour uniAdditional Prep Fees May Apply